Sign In | Join Free | My chinaqualitycrafts.com
China Guangzhou rongan fire equipment co. LTD logo
Guangzhou rongan fire equipment co. LTD
Guangzhou rongan fire equipment co. LTD
Verified Supplier

2 Years

Home > FM200 Fire Suppression System >

1800m3 90L Cylinders Group FM200 Fire Suppression System Automatic Or Manual Start

Guangzhou rongan fire equipment co. LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

1800m3 90L Cylinders Group FM200 Fire Suppression System Automatic Or Manual Start

  • 1
  • 2

Brand Name : Rongxiao

Model Number : QMQ4.2/180W QMQ4.2/150W QMQ4.2/120W QMQ4.2/90W QMQ5.6/180W QMQ5.6/150W QMQ5.6/120W QMQ5.6/90W QMQ5.6/70W

Certification : CAL,CMA,CNAS,,CCC

Place of Origin : Guangzhou City, Guangdong Province, China

MOQ : 1 set

Price : Negotiation

Payment Terms : L/C, D/P, Western Union, T/T, Credit card

Supply Ability : 18000 sets per week

Delivery Time : 10 days, subject to quantity negotiation

Packaging Details : Plywood outer box with bubble bag or paper

Detection System : Fire & Smoke Detectors

Transport Package : Plywood Outer Box Or Wooden Case

Operating Temperature : 0°C to 50°C

Agent : FM200 (HFC-227ea)

Actuation : Automatic or manual start

Discharge Time : 10 seconds

Usage : fire rescue system

Standard Of Examination : GB25972-2010

Contact Now

Equipment technical performance parameters:

Temperature℃ Pressure Mpa(20℃) Power Supply
design temperature usage temperature Fire extinguishing agent bottle group Nitrogen-driven bottle group

Main electricity

Standby power

0-50 0-50 0.3 13.5

AC

220V

DC24V

bottle group specifications and storage pressure

Bottle group name Model specification (l) Storage pressure (20℃)
Nitrogen start-up bottle group 8 6Mpa
Nitrogen automatic bottle group 70 13.5Mpa
Fire extinguishing agent bottle group 70 90 120 150 180

0.3Mpa

System maintenance and upkeep:

The daily maintenance and inspection of the HFC-227ea fire extinguishing system should be carried out by specially trained and qualified managers who are responsible for regular inspection, maintenance and management. Managers should be familiar with the performance, structure, action procedures, working status and technical regulations of the automatic fire extinguishing system, and be familiar with the methods of automatic control, manual control and mechanical emergency operation.

The specific contents of daily maintenance and upkeep include: checking and cleaning all equipment, checking and maintaining important equipment and pipelines, checking and maintaining system functions, checking the pressure status of pressure gauges, etc. And record the results of each inspection in detail. Equipment components that do not meet the requirements of the specifications should be replaced.

Emergency treatment of fire in gas extinguishing area:

1. When a fire occurs in the substation room, the fire is weak and controllable.

The on-duty personnel can immediately extinguish the fire with a fire extinguisher. And notify the central control room and the leadership department. (The distribution room is equipped with a fire telephone extension)

2. When a fire occurs in the substation room, the fire is large and spreads rapidly.

1. The on-duty personnel notify the on-duty personnel in the central control room of the fire and switch the alarm host to automatic state. The duty personnel in the duty room switch the gas fire extinguishing controller to the automatic state. Fire extinguishing is carried out through fire linkage. At the same time, the fire emergency plan of the property department is activated.

2. The duty personnel in the distribution room can directly press and hold the red "manual start" button on the gas fire extinguishing control panel, and start the fire extinguishing agent to extinguish the fire after a 30-second delay. Or use the emergency start and stop button to start the fire extinguishing agent to extinguish the fire. At the same time, the fire emergency plan of the property department is activated. (If the manual start fails, the mechanical emergency manual control method is used to start the fire extinguishing agent to extinguish the fire)

3. If the fire is serious and is not extinguished by the fire extinguishing agent. After notifying the central control room or the leadership department, the fire emergency plan is activated, and the scene is quickly left to cooperate with the evacuation of personnel and assist in fire fighting.

1800m3 90L Cylinders Group FM200 Fire Suppression System Automatic Or Manual Start

Company introduction:

Guangzhou Rongan Fire Protection Equipment Co., Ltd. is a professional manufacturer of fire protection facilities integrating R&D, production, design and sales services. The company has experts from the national fire protection industry standards committee and a group of professional technical service teams with more than ten years of experience in the fire protection industry, and will spare no effort to provide you with the most intimate and professional comprehensive technical solutions for fire protection engineering products. "Rongxiao" series products produced by the company have passed the national compulsory product certification and the national fixed fire extinguishing system inspection center, with reliable quality and stable performance, and the factory has passed the ISO9001 quality system certification.

Frequently asked questions:

Q1: Are you a manufacturer or a trading company? A1: We are manufacturers.

Q2: How long is the delivery time? A2:10 days, which can be negotiated according to the quantity.

Q3: How to deal with the fault? A3: During the warranty period, we will provide you with a remote emergency plan during working hours. During the free maintenance period, the company will replace spare parts or complete machines that have failed due to defects or quality problems free of charge.


Product Tags:

90L FM200 Fire Suppression System

      

1800m3 FM200 Fire Suppression System

      
Quality 1800m3 90L Cylinders Group FM200 Fire Suppression System Automatic Or Manual Start for sale

1800m3 90L Cylinders Group FM200 Fire Suppression System Automatic Or Manual Start Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou rongan fire equipment co. LTD
*Subject:
*Message:
Characters Remaining: (0/3000)